MX4PB Combination Soft Starter with EMX4i Technology (700HP, 460V Heavy Duty – 904A max) 65K
Extended Part No: MX4PB-HD-700-4-4-HB
Combination soft starter with run duty integral bypass, 1200A circuit breaker and NEMA4 enclosure.
Max Amp Rating: 450% for 30 seconds, 1.25 Service Factor
Heavy Duty: 700HP 480VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
MX4PB Combination Soft Starter with EMX4i Technology (600HP, 460V Heavy Duty – 720A max) 65K
Extended Part No: MX4PB-HD-600-4-4-HB
Combination soft starter with run duty integral bypass, 1200A circuit breaker and NEMA4 enclosure.
Max Amp Rating: 450% for 30 seconds, 1.25 Service Factor
Heavy Duty: 600HP 480VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
MX4PB Combination Soft Starter with EMX4i Technology (500HP, 460V Heavy Duty – 590A max) 65K
Extended Part No: MX4PB-HD-500-4-4-HB
Combination soft starter with run duty integral bypass, 1200A circuit breaker and NEMA4 enclosure.
Max Amp Rating: 450% for 30 seconds, 1.25 Service Factor
Heavy Duty: 500HP 480VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
MX4PB Combination Soft Starter with EMX4i Technology (400HP, 460V Heavy Duty – 477A max) 65K
Extended Part No: MX4PB-HD-400-4-4-HB
Combination soft starter with run duty integral bypass, 800A circuit breaker and NEMA4 enclosure.
Max Amp Rating: 450% for 30 seconds, 1.25 Service Factor
Heavy Duty: 400HP 480VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RX4E Combination Soft Starter with MX4 Technology (600HP, 480V Heavy Duty – 720A max – NEMA 12) 65k
Extended Part No: RX4E-600-480-12KP-HB
Low voltage soft starter with across the line bypass, 1200A circuit breaker, NEMA 12 enclosure
Heavy Duty: 600HP 480VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RX4E Combination Soft Starter with MX4 Technology (500HP, 480V Heavy Duty – 590A max – NEMA 12) 65k
Extended Part No: RX4E-500-480-12KP-HB
Low voltage soft starter with across the line bypass, 1200A circuit breaker, NEMA 12 enclosure
Heavy Duty: 500HP 480VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RX4E Combination Soft Starter with MX4 Technology (400HP, 480V Heavy Duty – 477A max – NEMA 12) 65k
Extended Part No: RX4E-400-480-12KP-HB
Low voltage soft starter with across the line bypass, 800A circuit breaker, NEMA 12 enclosure
Heavy Duty: 400HP 480VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
EMX4i Full Featured Protected Chassis Soft Starter (200HP, 230V / 450HP, 460V STD Duty)
Extended Part No: EMX4i-0940B-V5-C1-H
Advanced, protected chassis solid state soft starter with built-in bypass, 350% current for 30 seconds (standard duty), 450% for 30 seconds (heavy duty), line voltage 200- 525 volts AC.
Standard Duty: 200HP, 230V / 450HP, 460V – 590A max
Heavy Duty: 150HP, 230V / 350HP, 460V – 480A max
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RX4E Combination Soft Starter with MX4 Technology (300HP, 480V Heavy Duty – 361A max – NEMA 3R) 65k
Extended Part No: RX4E-300-480-3RKP-HB
Low voltage soft starter with across the line bypass, 600A circuit breaker, NEMA 3R enclosure
Heavy Duty: 300HP 480V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RX4E Combination Soft Starter with MX4 Technology (150HP, 480V Heavy Duty – 180A max – NEMA 3R) 65k
Extended Part No: RX4E-150-480-3RKP-HB
Low voltage soft starter with across the line bypass, 300A circuit breaker, NEMA 3R enclosure
Heavy Duty: 150HP 480V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RX4E Combination Soft Starter with MX4 Technology (125HP, 480V Heavy Duty – 156A max – NEMA 3R) 65k
Extended Part No: RX4E-125-480-3RKP-HB
Low voltage soft starter with across the line bypass, 225A circuit breaker, NEMA 3R enclosure
Heavy Duty: 125HP 480VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RX4E Combination Soft Starter with MX4 Technology (200HP, 480V Heavy Duty – 240A max – NEMA 12) 65K
Extended Part No: RX4E-200-480-12KP-HB
Low voltage soft starter with across the line bypass, 400A circuit breaker, NEMA 12 enclosure
Heavy Duty: 200HP 480VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RX4E Combination Soft Starter with MX4 Technology (125HP, 480V Heavy Duty – 156A max – NEMA 12) 65k
Extended Part No: RX4E-125-480-12KP-HB
Low voltage soft starter with across the line bypass, 225A circuit breaker, NEMA 12 enclosure
Heavy Duty: 125HP 480VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RX4E Combination Soft Starter with MX4 Technology (100HP, 480V Heavy Duty – 124A max – NEMA 3R) 65k
Extended Part No: RX4E-100-480-3RKP-HB
Low voltage soft starter with across the line bypass, 225A circuit breaker, NEMA 3R enclosure
Heavy Duty: 100HP 480VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RX4E Combination Soft Starter with MX4 Technology (50HP, 480V Heavy Duty – 65A max – NEMA 12) 65k
Extended Part No: RX4E-050-480-12KP-HB
Low voltage soft starter with across the line bypass, 100A circuit breaker, NEMA 12 enclosure
Heavy Duty: 50HP 480VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RX4E Combination Soft Starter with MX4 Technology (75HP, 480V Heavy Duty – 96A max – NEMA 12) 65k
Extended Part No: RX4E-075-480-12KP-HB
Low voltage soft starter with across the line bypass, 225A circuit breaker, NEMA 12 enclosure
Heavy Duty: 75HP 480VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
EMX4e Cost Optimized Protected Chassis Soft Starter (150HP, 230V / 350HP, 460V)
Extended Part No: EMX4e-0550B-V5-C1-H
Low voltage soft starter with a built-in bypass, ideal for pump and fan applications.
Standard Duty: 350% current for 30 seconds, line voltage 200- 525 volts AC. Simple setup and commissioning, 120v control power required.
Standard Duty: 150HP 230V / 350HP 460VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
CSXi Pump Panel Soft Starter (200HP/575VAC)
Extended Part No: CSXi-0180-5-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 200HP 575V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
CSXi Pump Panel Soft Starter (150HP/575VAC)
Extended Part No: CSXi-0156-5-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 150HP 575V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
CSXi Pump Panel Soft Starter (125HP/575VAC)
Extended Part No: CSXi-0125-5-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 125HP 575V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
CSXi Pump Panel Soft Starter (100HP/575VAC)
Extended Part No: CSXi-0096-5-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 100HP 575V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
CSXi Pump Panel Soft Starter (75HP/575VAC)
Extended Part No: CSXi-0077-5-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 75HP 575V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
CSXi Pump Panel Soft Starter (60HP/575VAC)
Extended Part No: CSXi-0065-5-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 60HP 575V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
CSXi Pump Panel Soft Starter (50HP/575VAC)
Extended Part No: CSXi-0052-5-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 50HP 575V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
CSXi Pump Panel Soft Starter (40HP/575VAC)
Extended Part No: CSXi-0040-5-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 40HP 575V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
CSXi Pump Panel Soft Starter (30HP/575VAC)
Extended Part No: CSXi-0034-5-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 30HP 575V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
CSXi Pump Panel Soft Starter (15HP/575VAC)
Extended Part No: CSXi-0014-5-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 15HP 575V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
CSXi Pump Panel Soft Starter (75HP/230VAC)
Extended Part No: CSXi-0180-2-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 75HP 230V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
CSXi Pump Panel Soft Starter (60HP/230VAC)
Extended Part No: CSXi-0156-2-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 60HP 230V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
CSXi Pump Panel Soft Starter (50HP/230VAC)
Extended Part No: CSXi-0125-2-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 50HP 230V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
CSXi Pump Panel Soft Starter (30HP/230VAC)
Extended Part No: CSXi-0077-2-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 30HP 230V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
CSXi Pump Panel Soft Starter (20HP/230VAC)
Extended Part No: CSXi-0052-2-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 20HP 230V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.