• 0Shopping Cart
Benshaw Inc.
  • Home
  • About Us
    • Overview
    • News and Events
    • Regional Support Centers
    • Leadership Team
    • Media Center
    • Careers
  • Industries Served
    • HVAC/Refrigeration
    • Irrigation & Agriculture
    • Continuous Process Industries
    • Mining/Aggregates/Cement
    • Water/Wastewater
    • Oil & Gas
    • Marine
    • OEM
  • Motor Control Solutions
    • Low Voltage Controls
      • Overview
      • LV Soft Starters
      • Low Voltage Drives
      • Line and Load Reactors
      • Full Voltage Motor Controls
      • OEM Motor Controls
      • Specialty Products
      • Circuit Breakers
    • Medium Voltage Controls
      • Overview
      • MV Soft Starters
      • Full Voltage Assemblies
      • MV Switchgear Assemblies
      • Line-Ups/Motor Control Centers
      • MV Variable Frequency Drives
      • MV IEC Motor Controls
      • Specialty Products
      • Projects
    • Services
      • Overview
      • Commissioning
      • On-Site/Field Service Solutions
      • Warranty & Return Service:
        • Canada
        • USA
      • Factory Service
      • Retrofits
    • Resources
      • Request a Proposal
      • Browse our Document Library
      • Newsletter Subscription
      • Recent News
      • FAQs
  • Contact Us
  • Webstore
    • Shop (USA)
    • Switch to Canadian Webstore
    • View My Account
    • View My Shopping Cart
    • Open Shipment Tracking Tool
    • Checkout
  • Search
  • Menu
You are here: Home / Benshaw Express / Low Voltage Soft Starters / Packaged Starters / ATL Bypass / RX2E Combination Soft Starter with MX2 Technology (400HP, 480V Severe Duty...
RX2E Combination Soft Starter with MX2 Technology

RX2E Combination Soft Starter with MX2 Technology (400HP, 480V Severe Duty – NEMA3R)

$25,561.00

Extended Part No: RX2E-400-480-3RKP

Low voltage soft starter with an across the line bypass, 800A circuit breaker, NEMA3R enclosure

Heavy Duty: 400HP 480V

Product Documents

Catalog Page(s)

  • Web Optimized Catalog File (PDF)

Product Manual(s)

  • Users Guide

Drawings(s)

  • Schematic

Backorders allowed. Please consult factory for estimated shipping date on backordered items.

Part No: 2100724 Categories: ATL Bypass, Low Voltage Soft Starters, Packaged Starters, RX2E
  • Detailed Description
  • Other Attributes

Benshaw RX2E Enclosed Combo Starters are severe duty rated, dual redundant soft starters for the most difficult and critical applications. They include a circuit breaker, full voltage rated emergency bypass contactor, door mounted Start/Stop pushbuttons, Local/Off/Remote selector switch and door mounted MX2 keypad.

RX2E combo starters are available in either a NEMA12 or NEMA3R enclosure. The full voltage rated bypass contactor doubles as a running duty bypass contactor when in soft starter mode. Benshaw’s MX2 control technology provides basic motor protection with adjustable overload setting and adjustable motor ramp profiles that can be tailed to the motor load. The RX2 can be programmed using the door mounted LCD keypad or Modbus register mapping.

Standard stock models are available for immediate shipment (480V ratings up to 600HP) and include Benshaw’s exclusive three-year warranty.

Weight 765 lbs
Dimensions Height 87 in x Width 37 in x Depth 20 in.

Related products

  • CSXi Compact Protected Chassis Soft Starter (15HP, 230V / 30HP, 460V / 40HP, 575V)

    CSXi Compact Protected Chassis Soft Starter (15HP, 230V / 30HP, 460V / 40HP, 575V)

    Extended Part No: CSXi-018-V6-C1

    Low voltage soft starter with a built-in bypass, ideal for pump and fan applications.

    400% current for 6 seconds / Max amps @ 50 degrees C: 42A. Simple setup and commissioning. 120v control power required.

    Standard Duty: 15HP,230V / 30HP,460V / 40HP,575V

    $958.00

    14 in stock

    Add to cart Show Details
  • Part No 2119091

    EMX4e Cost Optimized Protected Chassis Soft Starter (30HP, 230V / 60HP, 460V)

    Extended Part No: EMX4e-0115B-V5-C1-H

    Low voltage soft starter with a built-in bypass, ideal for pump and fan applications.

    Standard Duty: 350% current for 30 seconds, line voltage 200- 525 volts AC. Simple setup and commissioning, 120v control power required.

    Standard Duty: 30HP, 230V / 60HP, 460V

    $2,038.00
    Add to cart Show Details
  • CSXi Compact Protected Chassis Soft Starter (5HP, 230V / 10HP, 460V / 15HP, 575V)

    CSXi Compact Protected Chassis Soft Starter (5HP, 230V / 10HP, 460V / 15HP, 575V)

    Extended Part No: CSXi-007-V6-C1

    Low voltage soft starter with a built-in bypass, ideal for pump and fan applications.

    400% current for 6 seconds / Max amps @ 50 degrees C: 17A. Simple setup and commissioning. 120v control power required.

    Standard Duty: 5HP,230V / 10HP,460V / 15HP,575V

    $736.00

    23 in stock

    Add to cart Show Details
  • CSXi Series Compact Soft Starter

    CSXi Compact Protected Chassis Soft Starter (20HP, 230V / 40HP, 460V / 50HP, 575V)

    Extended Part No: CSXi-030-V6-C1

    Low voltage soft starter with a built-in bypass, ideal for pump and fan applications.

    400% current for 6 seconds / Max amps @ 50 degrees C: 55A. Simple setup and commissioning. 120v control power required.

    Standard Duty: 20HP,230V / 40HP,460V / 50HP,575V

    $1,165.00

    21 in stock

    Add to cart Show Details

Benshaw Inc.

Benshaw, Inc.
615 Alpha Drive
Pittsburgh, PA 15238
United States

Benshaw Canada Controls, Inc.
550 Bright Street East
Listowel, Ontario N4W 3W3
Canada

News and Events

  • Benshaw Product Catalog Updates2023 Catalog UpdatesJanuary 13, 2023 - 11:04 am
  • Ball Mill PositioningBall Mill PositioningNovember 16, 2022 - 9:37 am
  • Benshaw M2L Series Medium Voltage VFDMedium Voltage VFD Provides Major Cost SavingsSeptember 28, 2022 - 2:27 pm
  • Aggregate Industry ApplicationsBenshaw Joins OAIMASeptember 23, 2022 - 1:06 pm
  • Motor Control in Pumping ApplicationsMotor Control in Pumping ApplicationsSeptember 15, 2022 - 12:10 pm

Benshaw Inc.

QuickLinks

  • Contact Us
  • Low Voltage Controls
  • Medium Voltage Controls
  • Proposal Request Form
  • Document Library
  • Webstore
© Copyright 2023 - Benshaw Inc.
  • Facebook
  • LinkedIn
  • Benshaw Partner Portal
  • Terms of Use
  • Privacy
RX2E Combination Soft Starter with MX2 Technology (50HP, 480V Severe Duty –... Part No 2100708 Part No 2100742 RX3E Combination Soft Starter with MX3 Technology (200HP, 480V Severe Duty –...
Scroll to top

This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies.

OK×

Cookie and Privacy Settings



How we use cookies

We may request cookies to be set on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience, and to customize your relationship with our website.

Click on the different category headings to find out more. You can also change some of your preferences. Note that blocking some types of cookies may impact your experience on our websites and the services we are able to offer.

Essential Website Cookies

These cookies are strictly necessary to provide you with services available through our website and to use some of its features.

Because these cookies are strictly necessary to deliver the website, refuseing them will have impact how our site functions. You always can block or delete cookies by changing your browser settings and force blocking all cookies on this website. But this will always prompt you to accept/refuse cookies when revisiting our site.

We fully respect if you want to refuse cookies but to avoid asking you again and again kindly allow us to store a cookie for that. You are free to opt out any time or opt in for other cookies to get a better experience. If you refuse cookies we will remove all set cookies in our domain.

We provide you with a list of stored cookies on your computer in our domain so you can check what we stored. Due to security reasons we are not able to show or modify cookies from other domains. You can check these in your browser security settings.

Google Analytics Cookies

These cookies collect information that is used either in aggregate form to help us understand how our website is being used or how effective our marketing campaigns are, or to help us customize our website and application for you in order to enhance your experience.

If you do not want that we track your visist to our site you can disable tracking in your browser here:

Other external services

We also use different external services like Google Webfonts, Google Maps, and external Video providers. Since these providers may collect personal data like your IP address we allow you to block them here. Please be aware that this might heavily reduce the functionality and appearance of our site. Changes will take effect once you reload the page.

Google Webfont Settings:

Google Map Settings:

Google reCaptcha Settings:

Vimeo and Youtube video embeds:

Privacy Policy

You can read about our cookies and privacy settings in detail on our Privacy Policy Page.

Privacy
Accept settingsHide notification only