- Display 45 Products per page
-
CSXi Compact Protected Chassis Soft Starter (75HP, 230V / 150HP, 460V / 200HP, 575V)
Extended Part No: CSXi-110-V6-C1
Low voltage soft starter with a built-in bypass, ideal for pump and fan applications.
400% current for 6 seconds / Max amps @ 50 degrees C: 186A. Simple setup and commissioning. 120v control power required.
Standard Duty: 75HP,230V / 150HP,460V / 200HP,575V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RB3 Open Chassis Soft Starter with MX3 Technology (240-575V – 52A max)
Extended Part No: RB3-1-S-052A-12C
Run duty integral bypass, open chassis soft starter with Benshaw MX3 technology
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
CSXi Pump Panel Soft Starter (200HP/575VAC)
Extended Part No: CSXi-0180-5-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 200HP 575V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
MX4PB Combination Soft Starter with EMX4i Technology (100HP, 240V Standard Duty – 248A max) 65K
Extended Part No: MX4PB-SD-100-2-4-HB
Combination soft starter with run duty integral bypass, 400A circuit breaker and NEMA4 enclosure.
Max Amp Rating: 350% for 30 seconds, 1.15 Service Factor
Standard Duty: 100HP 240VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
EMX4i Full Featured Protected Chassis Soft Starter (200HP 460V STD Duty, 150HP 460V HD DUTY)
Extended Part No: EMX4i-0352B-V5-C1-H
Advanced, protected chassis solid state soft starter with built-in bypass, 350% current for 30 seconds (standard duty), 450% for 30 seconds (heavy duty), line voltage 200-525 volts AC.
Standard Duty: 75HP, 230V / 200HP, 460V – 240A max
Heavy Duty: 60HP, 230V / 150HP, 460V – 180A max
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RB3 Open Chassis Soft Starter with MX3 Technology (240-575V – 477A max)
Extended Part No: RB3-1-S-477A-17C
Run duty integral bypass, open chassis soft starter with Benshaw MX3 technology
Standard Duty: 200HP, 240V / 400HP, 480V / 500HP, 575V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RX2E Combination Soft Starter with MX2 Technology (50HP, 480V Severe Duty – NEMA 12)
Extended Part No: RX2E-050-480-12KP
Low voltage soft starter with an across the line bypass, 100A circuit breaker, NEMA 12 enclosure
Heavy Duty: 50HP 480VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
CSXi Pump Panel Soft Starter (150HP/460VAC)
Extended Part No: CSXi-0180-4-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 150HP, 460V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
EMX4i Full Featured Non-Bypass Protected Chassis Soft Starter (400HP, 230V / 800HP, 460V STD Duty)
Extended Part No: EMX4i-1220C-V5-C1-H
Advanced, non-bypass protected chassis solid state soft starter, 350% current for 30 seconds (standard duty), 450% for 30 seconds (heavy duty), line voltage 200- 525 volts AC.
Standard Duty: 400HP, 230V / 800HP, 460V – 966A max
Heavy Duty: 300HP, 230V / 600HP, 460V – 784A max
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RX2E Combination Soft Starter with MX2 Technology (300HP, 480V Severe Duty – NEMA 12)
Extended Part No: RX2E-300-480-12KP
Low voltage soft starter with an across the line bypass, 600A circuit breaker, NEMA 12 enclosure
Heavy Duty: 300HP 480V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RB3 Open Chassis Soft Starter with MX3 Technology (240-575V – 180A max)
Extended Part No: RB3-1-S-180A-15C
Run duty integral bypass, open chassis soft starter with Benshaw MX3 technology
Standard Duty: 75HP, 240V / 150HP, 480V / 200HP, 575V
Heavy Duty: 50HP, 240V / 100HP, 480V / 125HP, 575V
Severe Duty: 40HP, 240V / 75HP, 480V / 100HP, 575VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RX3E Combination Soft Starter with MX3 Technology (500HP, 480V Severe Duty – 590A max – NEMA 12)
Extended Part No: RX3E-500-480-12KP
Low voltage soft starter with an across the line bypass, 1200A circuit breaker, NEMA 12 enclosure
Heavy Duty: 500HP 480V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RX2E Combination Soft Starter with MX2 Technology (125HP, 480V Severe Duty – NEMA 12)
Extended Part No: RX2E-125-480-12KP
Low voltage soft starter with an across the line bypass, 225A circuit breaker, NEMA 12 enclosure
Heavy Duty: 125HP 480V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
MX4PB Combination Soft Starter with EMX4i Technology (150HP, 460V Heavy Duty – 180A max) 65K
Extended Part No: MX4PB-HD-150-4-4-HB
Combination soft starter with run duty integral bypass, 300A circuit breaker and NEMA4 enclosure.
Max Amp Rating: 450% for 30 seconds, 1.25 Service Factor
Heavy Duty: 150HP 480VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
CSXi Pump Panel Soft Starter (75HP/230VAC)
Extended Part No: CSXi-0180-2-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 75HP 230V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RX2E Combination Soft Starter with MX2 Technology (400HP, 480V Severe Duty – NEMA 12)
Extended Part No: RX2E-400-480-12KP
Low voltage soft starter with an across the line bypass, 800A circuit breaker, NEMA 12 enclosure
Heavy Duty: 400HP 480V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RX3E Combination Soft Starter with MX3 Technology (200HP, 480V Severe Duty – 240A max – NEMA 12)
Extended Part No: RX3E-200-480-12KP
Low voltage soft starter with an across the line bypass, 400A circuit breaker, NEMA 12 enclosure
Heavy Duty: 200HP 480V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
MX4PB Combination Soft Starter with EMX4i Technology (20HP, 240V Standard Duty – 54A max) 65K
Extended Part No: MX4PB-SD-020-2-4-HB
Combination soft starter with run duty integral bypass, 80A circuit breaker and NEMA4 enclosure.
Max Amp Rating: 350% for 30 seconds, 1.15 Service Factor
Standard Duty: 20HP 240VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RB3 Open Chassis Soft Starter with MX3 Technology (240-575V – 156A max)
Extended Part No: RB3-1-S-156A-14C
Run duty integral bypass, open chassis soft starter with Benshaw MX3 technology
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RX4E Combination Soft Starter with MX4 Technology (150HP, 480V Heavy Duty – 180A max – NEMA 3R) 65k
Extended Part No: RX4E-150-480-3RKP-HB
Low voltage soft starter with across the line bypass, 300A circuit breaker, NEMA 3R enclosure
Heavy Duty: 150HP 480V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RX4E Combination Soft Starter with MX4 Technology (500HP, 480V Heavy Duty – 590A max – NEMA 12) 65k
Extended Part No: RX4E-500-480-12KP-HB
Low voltage soft starter with across the line bypass, 1200A circuit breaker, NEMA 12 enclosure
Heavy Duty: 500HP 480VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RB3 Open Chassis Soft Starter with MX3 Technology (240-575V – 65A max)
Extended Part No: RB3-1-S-065A-12C
Run duty integral bypass, open chassis soft starter with Benshaw MX3 technology
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RB3 Open Chassis Soft Starter with MX3 Technology (240-575V – 414A max)
Extended Part No: RB3-1-S-414A-17C
Run duty integral bypass, open chassis soft starter with Benshaw MX3 technology
Standard Duty: 175HP, 240V / 350HP, 480V / 450HP, 575V
Heavy Duty: 150HP, 240V / 300HP, 480V / 400HP, 575V
Severe Duty: 125HP, 240V / 250HP, 480V / 300HP, 575VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
CSXi Pump Panel Soft Starter (125HP/575VAC)
Extended Part No: CSXi-0125-5-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 125HP 575V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.