- Display 45 Products per page
-
CSXi Pump Panel Soft Starter (150HP/460VAC)
Extended Part No: CSXi-0180-4-PP-N3R-CB-PD
Benshaw CSXi pump panels feature a NEMA3R enclosure with built-in bypass, 400% current for 6 seconds, circuit breaker with door operator 35kAIC, control power transformer, space heater with thermostat, start/stop pushbuttons, hand-off-auto, power on, run, fault pilot lights.
Standard Duty: 150HP, 460V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
MX4PB Combination Soft Starter with EMX4i Technology (600HP, 460V Heavy Duty – 720A max) 65K
Extended Part No: MX4PB-HD-600-4-4-HB
Combination soft starter with run duty integral bypass, 1200A circuit breaker and NEMA4 enclosure.
Max Amp Rating: 450% for 30 seconds, 1.25 Service Factor
Heavy Duty: 600HP 480VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
Circuit Breaker 30 A – 100 Frame 3P 600 VAC, N-Normal Fault, FTU Trip Unit, 35 KAIC Interrupt at 480 VAC
Extended Part No: R2CB-30A-100F-3P-NF-FTU
Three pole, fixed thermal and fixed magnet, 600 volt rated circuit breaker. Includes line and load lugs and mounting hardware.
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
Circuit Breaker 600 A – 600 Frame 3P 600 VAC, N-Normal Fault, FTU Trip Unit, 35 KAIC Interrupt at 480 VAC
Extended Part No: R2CB-600A-600F-3P-NF-FTU
Three pole, fixed thermal and fixed magnet, 600 volt rated circuit breaker. Includes line and load lugs and mounting hardware.
9 in stock (can be backordered)
-
Circuit Breaker 175 A – 250 Frame 3P 600 VAC, N-Normal Fault, FTU Trip Unit, 35 KAIC Interrupt at 480 VAC
Extended Part No: R2CB-175A-250F-3P-NF-FTU
Three pole, fixed thermal and fixed magnet, 600 volt rated circuit breaker. Includes line and load lugs and mounting hardware.
84 in stock (can be backordered)
-
Circuit Breaker 20 A – 100 Frame 3P 600 VAC, E-Standard Fault, FTU Trip Unit, 25 KAIC Interrupt at 480 VAC
Extended Part No: R2CB-20A-100F-3P-EF-FTU
Three pole, fixed thermal and fixed magnet, 600 volt rated circuit breaker. Includes line and load lugs and mounting hardware.
26 in stock (can be backordered)
-
Circuit Breaker 25 A – 100 Frame 3P 600 VAC, N-Normal Fault, FTU Trip Unit, 35 KAIC Interrupt at 480 VAC
Extended Part No: R2CB-25A-100F-3P-NF-FTU
Three pole, fixed thermal and fixed magnet, 600 volt rated circuit breaker. Includes line and load lugs and mounting hardware.
97 in stock (can be backordered)
-
Circuit Breaker 100 A – 100 Frame 3P 600 VAC, E-Standard Fault, FTU Trip Unit, 25 KAIC Interrupt at 480 VAC
Extended Part No: R2CB-100A-100F-3P-EF-FTU
Three pole, fixed thermal and fixed magnet, 600 volt rated circuit breaker. Includes line and load lugs and mounting hardware.
5 in stock (can be backordered)
-
EMX4i Full Featured Protected Chassis Soft Starter (15HP, 230V / 40HP, 460V STD Duty)
Extended Part No: EMX4i-0064B-V5-C1-H
Advanced, protected chassis solid state soft starter with built-in bypass, 350% current for 30 seconds (standard duty), 450% for 30 seconds (heavy duty), line voltage 200- 525 volts AC.
Standard Duty: 15HP, 230V / 40HP, 460V
Heavy Duty: 10HP, 230V / 25HP, 460V – 40A max
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
Circuit Breaker 1200 A – 1200 Frame 3P 600 VAC, H-High Fault, NG0 Trip Unit, 65 KAIC Interrupt at 480 VAC
Extended Part No: R2CB-1200A-1200F-3P-HF-NG0
Three pole, electronic trip, 600 volt rated circuit breaker. Includes line and load lugs and mounting hardware.
4 in stock (can be backordered)
-
Circuit Breaker 50 A – 150 Frame 3P 600 VAC, EH-Extra High Fault, FTU Trip Unit, 100 KAIC Interrupt at 480 VAC
Extended Part No: R2CB-50A-150F-3P-LF-FTU
Three pole, fixed thermal and fixed magnet, 600 volt rated circuit breaker. Includes line and load lugs and mounting hardware.
3 in stock (can be backordered)
-
EMX4i Full Featured Protected Chassis Soft Starter (10HP, 230V / 25HP, 460V STD Duty)
Extended Part No: EMX4i-0052B-V5-C1-H
Advanced, protected chassis solid state soft starter with built-in bypass, 350% current for 30 seconds (standard duty), 450% for 30 seconds (heavy duty), line voltage 200- 525 volts AC.
Standard Duty: 10HP, 230V / 25HP, 460V
Heavy Duty: 10HP, 230V / 20HP, 460V – 28A max
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
Circuit Breaker 90 A – 100 Frame 3P 600 VAC, N-Normal Fault, FTU Trip Unit, 35 KAIC Interrupt at 480 VAC
Extended Part No: R2CB-90A-100F-3P-NF-FTU
Three pole, fixed thermal and fixed magnet, 600 volt rated circuit breaker. Includes line and load lugs and mounting hardware.
30 in stock (can be backordered)
-
CSXi Compact Protected Chassis Soft Starter (15HP, 230V / 30HP, 460V / 40HP, 575V)
Extended Part No: CSXi-018-V6-C1
Low voltage soft starter with a built-in bypass, ideal for pump and fan applications.
400% current for 6 seconds / Max amps @ 50 degrees C: 42A. Simple setup and commissioning. 120v control power required.
Standard Duty: 15HP,230V / 30HP,460V / 40HP,575V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
MX4PB Combination Soft Starter with EMX4i Technology (200HP, 240V Heavy Duty – 477A max) 65K
Extended Part No: MX4PB-HD-200-2-4-HB
Combination soft starter with run duty integral bypass, 800A circuit breaker and NEMA4 enclosure.
Max Amp Rating: 450% for 30 seconds, 1.25 Service Factor
Heavy Duty: 200HP 240VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
RB3 Open Chassis Soft Starter with MX3 Technology (240-575V – 720A max)
Extended Part No: RB3-1-S-720A-19C
Run duty integral bypass, open chassis soft starter with Benshaw MX3 technology
Standard Duty: 300HP, 240V / 600HP, 480V / 700HP, 575V
Heavy Duty: 250HP, 240V / 500HP, 480V / 600HP, 575VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
MX4PB Combination Soft Starter with EMX4i Technology (250HP, 240V Heavy Duty – 590A max) 65K
Extended Part No: MX4PB-HD-250-2-4-HB
Combination soft starter with run duty integral bypass, 1000A circuit breaker and NEMA4 enclosure.
Max Amp Rating: 450% for 30 seconds, 1.25 Service Factor
Heavy Duty: 250hp 240V
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
Circuit Breaker 100 A – 150 Frame 3P 600 VAC, H-High Fault, FTU Trip Unit, 65 KAIC Interrupt at 480 VAC
Extended Part No: R2CB-100A-150F-3P-HF-FTU
Three pole, fixed thermal and fixed magnet, 600 volt rated circuit breaker. Includes line and load lugs and mounting hardware.
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
MX4PB Combination Soft Starter with EMX4i Technology (75HP, 460V Heavy Duty – 96A max) 65K
Extended Part No: MX4PB-HD-075-4-4-HB
Combination soft starter with run duty integral bypass, 150A circuit breaker and NEMA4 enclosure.
Max Amp Rating: 450% for 30 seconds, 1.25 Service Factor
Heavy Duty: 75HP 480VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
Circuit Breaker 250 A – 250 Frame 3P 600 VAC, N-Normal Fault, FTU Trip Unit, 35 KAIC Interrupt at 480 VAC
Extended Part No: R2CB-250A-250F-3P-NF-FTU
Three pole, fixed thermal and fixed magnet, 600 volt rated circuit breaker. Includes line and load lugs and mounting hardware.
114 in stock (can be backordered)
-
EMX4i Full Featured Protected Chassis Soft Starter (100HP, 230V / 200HP, 460V STD Duty)
Extended Part No: EMX4i-0397B-V5-C1-H
Advanced, protected chassis solid state soft starter with built-in bypass, 350% current for 30 seconds (standard duty), 450% for 30 seconds (heavy duty), line voltage 200- 525 volts AC.
Standard Duty: 100HP, 230V / 200HP, 460V – 261A max
Heavy Duty: 75HP, 230V / 150HP, 460V – 203A max
Backorders allowed. Please consult factory for estimated shipping date on backordered items.
-
MX4PB Combination Soft Starter with EMX4i Technology (15HP, 240V Heavy Duty – 42A max) 65K
Extended Part No: MX4PB-HD-015-2-4-HB
Combination soft starter with run duty integral bypass, 70A circuit breaker and NEMA4 enclosure.
Max Amp Rating: 450% for 30 seconds, 1.25 Service Factor
Heavy Duty: 15HP 240VBackorders allowed. Please consult factory for estimated shipping date on backordered items.
-
Circuit Breaker 125 A – 150 Frame 3P 600 VAC, H-High Fault, FTU Trip Unit, 65 KAIC Interrupt at 480 VAC
Extended Part No: R2CB-125A-150F-3P-HF-FTU
Three pole, fixed thermal and fixed magnet, 600 volt rated circuit breaker. Includes line and load lugs and mounting hardware.
76 in stock (can be backordered)